AR  CZ  ES  FA  FR  HU  IT  JP  KR  PL  PT  RU  TR  CN 
Skip to main content

SOLITÄR® MIKROPOR M CANOPY

The acoustic cloud is made from perforated, galvanized sheet steel. The visible side of the acoustical cloud is covered with an acoustic fleece and coated in the desired colour tone. In addition to the standard colour tone Lahnau white you can choose from all customary special colours from RAL, Sikkens or NCS colour cards. The edges of the cloud are also coated in the same colour tone as the surface.

Depending on the desired degree of absorption a sound deadening inlay may be required in the acoustical cloud.

Inquire now

 

Advantages

  • Ideal for upgrading
  • Easily installed with filigree hangers
  • High light reflectance
  • Individually positionable

Base panel:
Electrolytic galvanized sheet steel to DIN 1541, perforated percentage of total area: 16-22%

Surface:
Acoustic membrane with matt, smooth and non-directional surface optionally available as sound absorbing (M) or sound reflecting (MT). Without visible perforation; consequently, no mineral wool covering required.

Standard formats:
2400 x 1200 x 40 mm or
1200 x 1200 x 40 mm
Custom formats on request

Surface colour (visible side):
In special colours matched to sample on request; optional antistatic, water-repellent special coating.

Mikropor® M Non-directional, fine-pore structured colour coating light reflectance value (white) > 90% (diffuse: 0.9).

Mikropor® M Patina Non-directional, matt, smooth coloured surface coating

Sound absorption level:

Acoustic test certificate on request or from the Download archive at
www.lahnau-akustik.de

Care / refurbishing:
It is possible to clean localized soiling using a damp synthetic sponge or brush. Clean with a vacuum cleaner and brush. Refurbishable by spraying with Wilhelmi acoustic paint (WAF-R), without any loss of sound absorption properties.

Tolerances:
The specifications issued by TAIM pertaining
to quality standards
for metal ceilings apply
to length, width and deflection.
All other dimensional details can deviate for
production-related reasons.

Hanging:
With thin wire hangers, wire lengths approx. 2000 mm, longer lengths available on request

Building material class:
A2 (s1, d0) (non-flammable)

Overview of the advantages of this system:
• Installs quickly and cleanly, including in occupied properties
• Retrospective improvements to the acoustics possible
• Can optionally also be used as a cooling acoustic cloud at any time (retrofit)
• Suitable for low installation heights
• Design freedom thanks to free-form design and colour schemes
• Economic solution thanks to low installation costs
• Very high degree of absorption
• Different edge versions offer design options (90°, angled or stepped).
 

 

Surface:
Acoustic membrane with matt, smooth and non-directional surface, optionally available as sound absorbing (M) or sound reflecting (MT). Without visible perforation; consequently, no mineral wool covering required

Surface colour (visible side):
In special colours as per sample on request; optional antistatic, water-repellent special coating

Mikropor® M
Non-directional, fine-pore structured colour coating light reflectance value (white) > 90% (diffuse: 0.9)

Mikropor® M Patina
Non-directional, matt, smooth coloured surface coating

ImagIo® M Design
Smooth, matt coloured surface in different patterns

(the colour and structure shown in images of surfaces can differ slightly from the original)

Note: Mikropor® M Imagio Design For surfaces see Acoustics in expanded glass granulate.

We would be more than happy to send you a sample.
Feel free to contact us.

We develop effective acoustic building materials in close cooperation with scientists, clients, architects and contractors. Utilizing these high-quality materials facilitates optimum speech intelligibility in our built-up environment.

At the same time, the design options available with regard to material, surface, colour and shape are so varied that it is possible to efficiently combine the demands placed on man and an eco-friendly architecture with one another on the basis of the latest scientific findings.

A variety of acoustics tests are available to download from the Download archive

Hanging
  • With thin wire hangers, wire lengths approx. 2000 mm, longer lengths available on request
  • With edge profiles and low suspended heights, with edge profiles on the rear of the panel and on the solid ceiling

You can download the complete installation instructions from the Download archive.

Installation

On site, fit the cross-members supplied with the wire hangers to the rear of the panel. Fit the bottom parts of the wire hangers to the cross-members. Fit the top parts of the wire hangers to the solid ceiling together with the wires. Feed the wires into the bottom parts of the wire hangers and adjust their height.
The wire hangers can easily be adjusted to any desired length

Installation detail
1. Cleaning
  • Before cleaning with a damp cloth, carefully remove surface dust with a brush or vacuum cleaner.
  • It is possible to remove localized soiling such as fingerprints or trails of soiling close to air outlets using a firm, damp sponge together with a commercially available household cleaner or Moisture-Clean (available as a powder from Lahnau Akustik) in the respective recommended concentrations.
  • Then carefully wash down the cleaned surface with clean, clear water and dab dry with an absorbent cloth or paper (kitchen roll).
  • We recommended you test clean an inconspicuous area each time before cleaning.

Professional refurbishment must be carried out using Wilhelmi acoustic paint WAF-R 86 (special colours WAF-R 87).

  • Quantity used during refurbishment: 400-700 g/m² depending on the degree of soiling
  • Ensure the room temperature does not fall below 12 °C when applying the coating; the relative humidity should not exceed 70%.
  • Once applied immediately ensure the rooms are ventilated and dehumidified.
2.1 Refurbishment

If the acoustic ceiling has become heavily soiled after many years of normal use and can no longer be cleaned properly, it is possible to restore it to a condition virtually as good as new by applying a refurbishment spray.

When applied professionally in accordance with the manufacturer’s instructions the acoustic absorbency of the wall or ceiling surface is not impaired. The refurbishment can be repeated several times, if required.

Under no circumstances should emulsion paints be applied to the surfaces using a brush or roller, otherwise the sound absorbing properties will be lost.

It is only possible to guarantee the acoustic characteristics will be retained by engaging a professional company that uses the appropriate coating machinery to professionally apply the refurbishment spray, e.g.,

Strobl Beschichtungstechnik GmbH
Hermann-Volz-Straße 50
D-88400 Biberach/Riß

Tel. +49 7351/4400-0
Fax +49 7351/4400-60
 

  • Schools & kindergartens
  • Theatres & concert halls
  • Banks & insurance offices
  • Private properties
  • Bars and restaurants
  • Hospitals
  • Office & administration